This is how it works
Leanbyte in the Assembly for Service provider
Error-free assembly due to guided step-by-step instructions
Verification by test pattern/video leads to high quality in assembly
Faster achievement of process stability through modelling of the process

Mounting of a GEZE TS 5000 Door closer

Work step
Prepare door
Transfer the assembly position to the door leaf using the enclosed stop position.
Target time: 55 seconds
1
Work step


Work step
Assemble closer body
Remove the slider before mounting. Fix the door closer with metric screws for an aluminium profile.
Target time: 1 minute 20 seconds
2
Work step


Work step
Mount closing times
Set closing time to 5-7 seconds at 90 ° door opening angle.
Target time: 1 minute
3